|
Persistent Identifier
|
perma:LIST.4GGCJZ |
|
Publication Date
|
2026-07-06 |
|
Title
| Top-Down Fabricated Silicon Nanowire Arrays for Field-Effect Detection of Prostate-Specific Antigen [* Cross-Reference *] |
|
Other Identifier
| https://doi.org/10.1021/acsomega.8b00990
SCOPUS_ID:85051133208 |
|
Author
| Rani, Dipti (Fachhochschule Kaiserslautern, Luxembourg Institute of Science and Technology)
Pachauri, Vivek (Fachhochschule Kaiserslautern, Rheinisch-Westfälische Technische Hochschule Aachen)Fachhochschule Kaiserslautern, Rheinisch-Westfälische Technische Hochschule AachenORCID0000-0003-3275-2429
Madaboosi, Narayanan (Instituto de Engenharia de Sistemas e Computadores, Lisbon, Stockholms universitet)
Jolly, Pawan (University of Bath, Department of Electronic & Electrical Engineering, Harvard Medical School)
Vu, Xuan Thang (Fachhochschule Kaiserslautern, Rheinisch-Westfälische Technische Hochschule Aachen, Rheinisch-Westfälische Technische Hochschule Aachen)
Estrela, Pedro (University of Bath, Department of Electronic & Electrical Engineering)University of Bath, Department of Electronic & Electrical EngineeringORCID0000-0001-6956-1146
Chu, Virginia (Instituto de Engenharia de Sistemas e Computadores, Lisbon)
Conde, João Pedro (Instituto de Engenharia de Sistemas e Computadores, Lisbon)
Ingebrandt, Sven (Fachhochschule Kaiserslautern, Rheinisch-Westfälische Technische Hochschule Aachen)Fachhochschule Kaiserslautern, Rheinisch-Westfälische Technische Hochschule AachenORCID0000-0002-0405-2727 |
|
Point of Contact
|
Use email button above to contact.
LIST RDS (LIST) |
|
Description
| Highly sensitive electrical detection of biomarkers for the early stage screening of cancer is desired for future, ultrafast diagnostic platforms. In the case of prostate cancer (PCa), the prostate-specific antigen (PSA) is of prime interest and its detection in combination with other PCa-relevant biomarkers in a multiplex approach is advised. Toward this goal, we demonstrate the label-free, potentiometric detection of PSA with silicon nanowire ion-sensitive field-effect transistor (Si NW-ISFET) arrays. To realize the field-effect detection, we utilized the DNA aptamer-receptors specific for PSA, which were covalently and site-specifically immobilized on Si NW-ISFETs. The platform was used for quantitative detection of PSA and the change in threshold voltage of the Si NW-ISEFTs was correlated with the concentration of PSA. Concentration-dependent measurements were done in a wide range of 1 pg/mL to 1 μg/mL, which covers the clinical range of interest. To confirm the PSA-DNA aptamer binding on the Si NW surfaces, a sandwich-immunoassay based on chemiluminescence was implemented. The electrical approach using the Si NW-ISFET platform shows a lower limit of detection and a wide dynamic range of the assay. In future, our platform should be utilized to detect multiple biomarkers in one assay to obtain more reliable information about cancer-related diseases. (2018-08-31)
***This entry has been automatically imported via Infodoc(ASO) CSV by LIST harvest scripts. Please refer to https://doi.org/10.1021/acsomega.8b00990 for the original and latest version of the dataset and data downloads*** (2026-06-10) |
|
Subject
| Physics |
|
Keyword
| early stage screening
ultrafast diagnostic platforms
Highly sensitive electrical
Highly sensitive
ultrafast diagnostic |
|
Funding Information
| European Commission: 317420 |
|
Deposit Date
| 2018-08-31 |
|
Data Type
| Article |
|
Data Source
| ACS Omega; eISSN: 24701343, vol. 3, n° 8, pp. 8471-8482 |